Efficacy and safety of left atrial appendage closure with WATCHMAN in patients with or without contraindication to oral anticoagulation: 1-Year follow-up outcome data of the EWOLUTION trial
Clinical Question
What is the real-world efficacy and safety of WATCHMAN left atrial appendage closure in patients with atrial fibrillation, particularly those contraindicated for oral anticoagulation?
Bottom Line
WATCHMAN left atrial appendage closure demonstrated high procedural success (98.5%) and low stroke rates (1.1% annually) in real-world practice, even in patients contraindicated for oral anticoagulation.
Major Points
- Largest prospective real-world registry of WATCHMAN device with 1025 patients
- 73% of patients were deemed unsuitable for oral anticoagulation therapy
- High-risk population with mean CHA2DS2-VASc score of 4.5 and 31% history of major bleeding
- Procedural success rate of 98.5% with adequate sealing (no leaks >5mm) in 99.7%
- Annual ischemic stroke rate of 1.1% representing 84% relative risk reduction vs expected
- Device thrombus occurred in 3.7% but was not correlated with stroke events
- Most patients managed with antiplatelet therapy rather than oral anticoagulation
Design
Study Type: Prospective multicenter registry
Randomization:
Blinding: None - open label registry
Enrollment Period: October 2013 to May 2015
Follow-up Duration: 1 year
Centers: 47
Countries: Netherlands, Germany, Russia, United Kingdom, Ireland, Italy, Belgium
Sample Size: 1025
Analysis: Kaplan-Meier method for mortality and device thrombus rates, log-rank tests for time-to-event analysis, Fisher exact test for binomial proportions
Inclusion Criteria
- Patients scheduled for WATCHMAN implant
- Eligible according to appropriate local and international guidelines
- Not participating in another trial
- Not pregnant or of childbearing age
- Willing, able, and of legal age to provide informed consent
Exclusion Criteria
- Participating in another clinical trial
- Pregnant or of childbearing potential
- Unable or unwilling to provide informed consent
Baseline Characteristics
| Characteristic | Control | Active |
|---|---|---|
| Age (years) | 73.4 ± 8.9 | |
| Age ≥75 years | 50.7% | |
| Female sex | 40.1% | |
| CHA2DS2-VASc score | 4.5 ± 1.6 | |
| HAS-BLED score | 2.3 ± 1.2 | |
| HAS-BLED ≥3 | 40.0% | |
| Contraindicated for OAC | 73.3% | |
| Congestive heart failure | 34.2% | |
| LVEF ≤40% | 13.2% | |
| Vascular disease | 41.9% | |
| Hypertension | 86.4% | |
| Diabetes | 29.7% | |
| Previous ischemic stroke/TIA | 30.5% | |
| Previous hemorrhagic stroke | 15.1% | |
| History of major bleeding | 31.3% | |
| Abnormal renal function | 15.8% | |
| Abnormal liver function | 4.3% |
Arms
| Field | WATCHMAN Device |
|---|---|
| Intervention | Percutaneous left atrial appendage closure with WATCHMAN device followed by antiplatelet therapy (83%) or vitamin K antagonists (8%) per physician discretion |
| Duration | Permanent device implantation with variable anticoagulation duration |
Outcomes
| Outcome | Type | Control | Intervention | HR / OR / RR | P-value |
|---|---|---|---|---|---|
| Procedural success and long-term stroke prevention | Primary | 98.5% implant success, 1.1% annual ischemic stroke rate | |||
| Adequate sealing (no leaks >5mm) | Secondary | 99.7% | |||
| Device thrombus | Secondary | 3.7% | |||
| Major bleeding (annual rate) | Secondary | 2.6% | |||
| Ischemic stroke/TIA/systemic embolism (annual rate) | Secondary | 1.5% | |||
| All-cause mortality at 1 year | Adverse | 9.8% | |||
| Procedure-related serious adverse events within 7 days | Adverse | 2.8% | |||
| Periprocedural death within 7 days | Adverse | 0.4% |
Subgroup Analysis
No differences in death, stroke, or bleeding rates were observed between patients with or without contraindication to anticoagulation. Half of stroke patients were still on discharge medication, half had changed to lower anticoagulation.
Criticisms
- Lack of control arm limits full assessment of therapy benefit
- Non-uniform postprocedural antithrombotic regimen at physician discretion
- 13% of patients lacked follow-up TEE/CT evaluation
- Primary follow-up responsibility with participating centers rather than centralized
- HAS-BLED bleeding risk calculations based on VKA patients may overestimate benefit in VKA-ineligible population
- Detailed device thrombus management not systematically captured
Funding
Boston Scientific Corporation provided funding for the study
Based on: EWOLUTION (Heart Rhythm, 2017)
Authors: Lucas V. Boersma, Hueseyin Ince, Stephan Kische, ..., Martin W. Bergmann
Citation: Heart Rhythm 2017;14:1302–1308